(Optional) Force Detectors and Applicable Grips
Force Detector and Grip for Flat Plate Samples
Force Detector
Model | SHL-10 kN-P |
---|---|
Part number | 346-77909-01 |
Capacity | Maximum 10 kN (tensile) |
High-Speed Grip for Flat Plate Samples
Model | High-speed grip for flat plate samples |
---|---|
Part number | 346-77160-02 |
Capacity | Maximum 10 kN (tensile) |
Shape of Grip | Wedge shape: W 13 mm, H 15 mm, file teeth |
Applicable Sample | Flat plate: Width max. 13 mm, thickness 0.5 to 3 mm |
Load detector and grips for round rods
The grips for small rods can be attached to the force detector.
Note: Please contact us for manufacture of a different shape of specimens and grips.
Note: Different sizes can also be accommodated.
Grips for high-speed testing of round rods
Model | Round rod grips for high-speed tensile testing |
---|---|
Part number | 346-77184-01 |
Capacity | Maximum 10 kN (tension) |
Shape of Grip | M12 × 1.5 female threads |
Applicable Sample |
Round rod specimens with M12 × 1.5 threaded ends (threaded length of 20 mm or more) |
Optional Accessories Striker, Clamping Plates
Striker (with load detector)
Main striker unit and tip
Model name | Striker ø12.7 | Striker ø20 | Striker ø10 |
---|---|---|---|
Part No. for main unit |
339-83665-02 | 339-83665-03 | 339-83665-01 |
Part No. for tip |
347-40060-06 | 347-40062-09 | 347-41604-00 |
Capacity (puncture) | 10kN | 10 kN | 10 kN |
---|---|---|---|
Striker diameter | ø12.7 mm | ø20 mm | ø10 mm |
Related Standards | ASTM D 7363 | ISO 6603-2 | ISO 6603-2 |
Note: Striker units with other load capacities and shapes are supplied as options.
Clamping Plates
Clamping plates
Part number | 346-77213-02 | 346-77213-01 | 346-77213-03 |
---|---|---|---|
Hole diameter | ø76 mm | ø40 mm | ø100 mm |
Related Standards | ASTM | ISO | ISO |
Applicable specimen size | ☐100mm t = 1 to 3 mm |
☐60mm t = 1 to 3 mm |
☐140mm t = 1 to 3 mm |
Examples of striker-clamp combinations for specific standards
Related Standards | ISO 6603-2 | ISO 6603-2 | ASTM D 3763 |
---|---|---|---|
Striker diameter | ø20.0 mm | ø10.0 mm | ø12.7 mm |
Clamping plates | ø140 mm | ø100 mm | ø176 mm |
Remarks | Standard combination |
For fragile materials or low fracture strain |
- |
Note: Non-standards combinations are supplied as options.
Using an Optional Thermostatic Chamber
Acquire Data for Temperature-Dependent High-Speed Behavior
A thermostatic chamber (-40 to +150 °C) can be used to obtain temperature-dependent data for high-speed behavior.
Layout Diagram (same for HITS-PX and HITS-TX)
Install the main testing machine on the ground floor, on a concrete floor at least 200 mm thick (able to withstand 1500 kg). The machine includes springs and other measures to isolate vibration, but avoid installing the machine in locations prone to transmitting vibrations.