Shimadzu LC Driver for Chromeleon™ 7 - Especificaciones
Seamless control of Shimadzu LC
Product
Description |
---|
Shimadzu LC Driver for Chromeleon™ 7 (for 1 system) |
Compatible ROM Versions
Shimadzu LC Driver Ver. 3.20 Compatible with Chromeleon™ 7 supports the units with the following ROM versions. Update the ROM if necessary.
1) Nexera/Prominence
Unit | Model | Minimum required ROM version |
---|---|---|
System Controller | CBM-20A, CBM-20Alite | 3.70 |
Pump | LC-30AD | 3.21 |
LC-20ADXR | 2.12 | |
LC-20AD | 2.11 | |
LC-20AT | 2.01 | |
LC-20Ai | 1.01 | |
LC-20AB | 2.02 | |
Column Oven | CTO-30AS | 3.10 |
CTO-30A | 3.11 | |
CTO-20A / CTO-20AC | 2.10 | |
Autosampler | SIL-30ACMP | 3.21 |
SIL-30AC | 3.22 | |
SIL-20A (HT, UFLC), SIL-20AC (HT, UFLC), SIL-20AXR, SIL-20ACXR |
Old board: 1.31 New board: 2.12 |
|
Rack Changer II | 2.00 | |
Rack Changer, Rack Changer C | 1.11 | |
Subcontroller | Subcontroller VP (Option Box VP) | 5.22 |
Detector | SPD-M30A | 4.04 |
SPD-M20A | 2.03 | |
SPD-20A, SPD-20AV | Old board: 2.03 New board: 3.03 |
|
RF-20A, RF-20AXS | 2.02 | |
RID-20A | Old board: 1.04 New board: 2.04 |
|
Analog input board (PC-55N) | - |
Note: For Chromeleon 7 compatible Shimadzu LC driver Ver. 2.01 and later, authentication setting on the instrument is required during the installation of the driver. Check the compatible ROM versions of the CBM- 20A/lite and configure settings for the instrument connection key.
2) i-Series (for LC-2030/2040/2030 Plus/2040 Plus)
Unit | Model | Minimum required ROM version |
---|---|---|
i-Series | Unable to connect *1 | |
i-Series Plus | LC-2030 Plus,LC-2030C Plus,LC-2030C 3D Plus LC-2040C Plus,LC-2040C 3D Plus LC-2030C LT Plus LC-2040C MT Plus,LC-2040C 3D MT Plus |
3.02 |
External Detector | RF-20A, RF-20AXS | 2.02 |
RID-20A | Old board: 1.04 New board: 2.04 |
Note: For Chromeleon 7 compatible Shimadzu LC driver Ver. 2.01 and later, authentication setting on the instrument is required during the installation of the driver. Check the compatible ROM versions of the i-Series and configure settings for the instrument connection key.
*1 When using i-Series LC-2030/LC-2040 (non-Plus models), do not update the Chromeleon LC driver to version 3.20.
3) i-Series LC-2050/LC-2060
Unit | Model | Minimum required ROM version |
---|---|---|
i-Series LC-2050/LC-2060 |
LC-2050,LC-2050C,LC-2050C 3D LC-2050C LT LC-2060C,LC-2060C 3D LC-2060C 3D MT |
3.20 |
Mobile Phase Monitor | MPM-40 | 1.04 |
External Detector | SPD-M40 | 2.01 |
RF-20A, RF-20AXS | 2.02 | |
RID-20A | Old board: 1.04 New board: 2.04 |
Note: i-Series LC-2050/LC-2060 driver does not need the instrument connection key.
4) Nexera series
Unit | Model | Minimum required ROM version |
---|---|---|
System Controller | SCL-40, CBM-40, CBM-40lite | 1.20 |
Pump | LC-40D, LC-40D XR, LC-40B XR | 1.02 |
LC-40D XS, LC-40D X3, LC-40B X3 | 1.02 | |
LC-40D XSi | 1.07(*1) | |
LC-40i | 1.00(*2) | |
LC-20AB (including LC-Mikros in LC-20AB compatible mode) |
2.02 | |
Column Oven | CTO-40C | 1.00 |
CTO-40S | 1.00 | |
CTO-30A | 3.11 | |
Chemical reaction box | CRB-40 | 2.00(*3) |
Autosampler | ||
SIL-20A, SIL-20AC | Old board: 1.32 New board: 2.13 |
|
SIL-30ACMP | 3.21 | |
SIL-40, SIL-40C, SIL-40 XR, SIL-40C XR SIL-40C XS, SIL-40C X3 |
1.05(*4) | |
SIL-40C XSi | 1.10(*1) (*4) | |
Plate Changer | 1.04(*4) | |
Detector | SPD-40, SPD-40V | 1.02 |
SPD-M40 | 2.01 | |
SPD-M30A | 4.04 | |
RF-20A, RF-20AXS | 2.02 | |
CDD-10Avp | 5.10 | |
RID-20A | Old board: 1.04 New board: 2.04 |
|
Optional board | - | |
Mobile Phase Monitor | MPM-40 | 1.02 |
Mobile Phase Flow Line Switching Valve |
LPGE Unit, FCV-11AL, FCV-11ALS UV recycle valve |
- |
High-Pressure Flow Line Switching Valve |
FCV-0206, FCV-0607, FCV-0206H FCV-0607H, FCV-0206H3, FCV-0607H3, FCV-0206H2i, FCV-0607H2i, FCV-36AH |
- |
FCV-BOX, FCV-S | - | |
FCV-DR | 1.02 |
- *1 To control this instrument, it is necessary to update the ROM version of the system controller to 1.60 or later.
- *2 To control this instrument, it is necessary to update the ROM version of the system controller to 1.62 or later.
- *3 To control this instrument, it is necessary to update the ROM version of the system controller to 1.43 or later.
- *4 When updated ROM version of Autosampler to 1.08 or later, please update the ROM version of Plate Changer to 1.08 or later too.
Note:
The [Nexera series] driver does not support other models such as LC-30AD.