    UV accessory selection guide for solids

    Agregar marcador

    Solid Samples

    Sample Analytical form and analytical condition Accessory
    Smooth Surface Samples* Transmittance Measurement Less than 3 mm thick Standard compartments+Film Holder, Cell Type Sample Holder, Glass/Film Holder for Standard Sample Compartment
    More than 3 mm thick Integrating Sphere Attachment (ISR-2600, ISR-2600Plus, ISR-603)
    Requires a large integrating sphere
    (due to ISO compliance and other reasons).
    Integrating Sphere Attachment, 150 mm Dia. (ISR-1503, ISR-1503F)
    Large sample size (over 100 mm square) Large-Sample Compartment (MPC-2600A/603A or SolidSpec-3700) Glass Sample Holder for MPC series/SolidSpec
    Reflectance Measurement Relative Specular Reflectance Measurement Normal measurement Specular Reflectance Measurement Attachment (5° incident angle)
    Large sample size (over 100 mm square) SolidSpec-3700 + Large Specular Reflectance Measurement Attachment (5° incident angle)
    Absolute Specular Reflectance Measurement 5゚ incident angle measurement Absolute Specular Reflectance Attachment (ASR-3105) (Requires a Large-Sample Compartment and
    BIS-3100/3700/603 Sample Base Plate Integrating Sphere Set separately).
    12/30/45゚ incident angle measurement Absolute Specular Reflectance Attachment (ASR-3112, ASR-3130, ASR-3145) (Requires a Large-Sample
    Compartment, BIS-3100/3700/603 Sample Base Plate Integrating Sphere Set, and polarizer assembly separately.)
    Variable Angle Measurement Unit Variable Angle Measurement Unit (Requires large-sample compartment and polarizer assembly separately.)
    Relative Diffuse Reflectance Measurement Normal measurement Integrating Sphere Attachment (ISR-2600, ISR-2600Plus, ISR-603)
    Requires a large integrating sphere
    (due to ISO compliance and other reasons).
    Integrating Sphere Attachment, 150 mm Dia. (ISR-1503, ISR-1503F)
    Large sample size (over 100 mm square) Large-Sample Compartment (MPC-2600A/603A, or SolidSpec-3700)
    Rough Surface Sample** Transmittance Measurement Normal measurement Integrating Sphere Attachment (ISR-2600, ISR-2600Plus, ISR-603)
    Requires a large integrating sphere
    (due to ISO compliance and other reasons).
    Integrating Sphere Attachment, 150 mm Dia. (ISR-1503, ISR-1503F)
    Large sample size (over 100 mm square) Large-Sample Compartment (MPC-2600A/603A, or SolidSpec-3700)
    Reflectance Measurement Relative Diffuse Reflectance Measurement Normal measurement Integrating Sphere Attachment (ISR-2600, ISR-2600Plus, ISR-603)
    Requires a large integrating sphere
    (due to ISO compliance and other reasons).
    Integrating Sphere Attachment, 150 mm Dia. (ISR-1503, ISR-1503F)
    Large sample size (over 100 mm square) Large-Sample Compartment (MPC-2600A/603A, or SolidSpec-3700)
    Absolute Diffuse Reflectance Measurement Consult your Shimadzu representative.
    (Depends on the sample. A method using conversion from the mirror reflectance, for instance, is available.)
    Large sample size (over 100 mm square) Large-Sample Compartment (MPC-2600A/603A, or SolidSpec-3700)
    Small sample size (below 5 mm square) Micro Sample Holder + Micro Beam Lens Unit

    * Metals with a mirror-finished surface, mirrors, transparent acrylic and films, etc.
    ** Paper, cloth, plastics, semi-transparent films, etc.

    For color measurement, the Color Measurement Software COL-UVPC is required separately.
    For film thickness measurement, the Film Thickness Measurement Software FLM-UVPC is required separately.