    Liquid Samples

    Sample Analytical form and analytical condition Accessory
    Transparent Sample Sample volume: 2.5 mL min. Standard Sample Compartment + 10 mm Cell
    Micro-volume measurement 1 mL min. Semi-Micro Cell + Micro Cell Holder with Mask
    500 µL min. Micro Cell + Micro Cell Holder with Mask
    50 µL min. Super-micro Cell + Super-micro Cell Holder
    For automatically measuring samples in multiple cells MMC-1600 8/16 Series Micro Multi-Cell Holders and Cells
    Samples with high absorbance, but that are difficult to dilute (short optical path measurement) Short-Path Cell (1, 2, 5 mm) + Spacer for Short-Path Cell
    Samples with low absorbance, but that are difficult to concentrate (long optical path measurement) Long-Path Cell (20, 30, 50, 100 mm) + Long-Path Rectangular Cell Holder
    For automatically measuring samples in multiple cells Normal measurement Multi-Cell Sample Compartment (sample volume: 2.5 mL min.)
    Small sample volumes (50 µL min.) MMC-1600 8/16 Series Micro Multi-Cell Holders and Cells
    Requires temperature control CPS-100 Six-Cell Thermoelectrically Temperature-Controlled Cell Positioner
    (sample volume: 2.5 mL min.)
    For temperaturecontrolled measurements
    (constanttemperature measurement)
    Temperature-controlled with water circulation Constant-Temperature Cell Holder + NTT-2200P Constant-Temperature Water Circulator
    Thermoelectrically temperature controlled Normal measurement TCC-100 Thermoelectrically Temperature-Controlled Cell Holder
    Multi Samples CPS-100 Six-Cell Thermoelectrically Temperature-Controlled Cell Positioner
    Tm Analysis / Temperature control S-1700 Thermoelectric Single Cell Holder
    Automatically supplies sample to flow cells
    (automatic analysis)
    Requires temperature control (constant-temperature water circulation) 160C Sipper Unit + NTT-2200P
    Temperature control not necessary 160L/160T/160U Sipper Unit (Select type based on liquid volume.)
    Requires accurate control of aspiration volume. Requires temperature control
    (constant-temperature water circulation)
    Syringe Sipper CN + NTT-2200P (Select flow cell based on liquid volume.)
    Temperature control not necessary Syringe Sipper N (Select flow cell based on liquid volume)
    For automating measurement of multiple samples Sipper Unit or Syringe Sipper + ASC-5 Auto Sample Changer
    Suspension Sample Absorption measurement of suspension samples Wavelength range: 240 nm min. Integrating Sphere Attachment (ISR-2600, ISR-2600Plus, ISR-603)
    For measuring UV region above 190 nm SolidSpec-3700DUV
    Turbidity measurement Light transmitted light turbidity measurement
    (commonly used measurement method)
    10/50 mm Cell + Long-Path Rectangular Cell Holder
    (Optical path length of cell depends on test method.)
    Integrating sphere turbidity measurement Integrating Sphere Attachment (ISR-2600, ISR-2600Plus, ISR-603)