Absolute Specular Reflectance Measurement - Especificaciones
Absolute Specular Reflectance Attachment
ASR series
This attachment measures the absolute reflectance of the specular reflected light. It is used to measure the absolute specular reflectance of a solid sample, such as a mirror, when mounted on the large-sample compartment or SolidSpec. The sample base plate integrating sphere set must also be mounted at the same time. Since measurement is influenced by polarized light when the angle of incidence is large (30°, 45°), the separate polarizer is required to accurately perform measurement.
- For UV-2600series/2700series/3600/3600Plus series, SolidSpec Series
- Approximate size of sample:
25 to 200 mm dia. or 20 x 20 to 150 x 150 mm, thickness up to 30 mm
ASR Attachment Name | Angle of Incidence | Measurement Wavelength Range |
---|---|---|
ASR3105 | 5° | 300 to 800 nm (when MPC-2600A is used) |
300 to 2400 nm (when MPC-3100/603A or SolidSpec is used) | ||
ASR3112 | 12° | 300 to 800 nm (when MPC-2600A is used) |
300 to 2500 nm (when MPC-3100/603A or SolidSpec is used) | ||
ASR3130 | 30° | 300 to 800 nm (when MPC-2600A is used) |
300 to 2300 nm (when MPC-3100/603A or SolidSpec is used) | ||
ASR3145 | 45° | 300 to 800 nm (when MPC-2600A is used) |
300 to 2300 nm (when MPC-3100/603A or SolidSpec is used) |
BIS-603/3100/3700/3700DUV Sample Base Plate Integrating Sphere Set
This set comprises a sample base plate and integrating sphere. It is required for mounting the absolute specular reflectance attachment onto the UV instrument.
- For UV-2600series/2700series/3600/3600Plus series, SolidSpec Series
Name | Applicable Instrument | Measurement Wavelength Range |
---|---|---|
BIS-603 | UV-3600 Plus series | 240 to 2600 nm |
BIS-3100 | UV-2600series /2700series | 240 to 800 nm |
UV-3600 | 240 to 2600 nm | |
BIS-3700 | SolidSpec-3700, SolidSpec-3700i | 240 to 2600 nm |
BIS-3700DUV | SolidSpec-3700DUV SolidSpec-3700i DUV | 175 to 2600 nm |
Large Polarizer Set, Polarizer Type I, II, III
This attachment is used to obtain accurate reflectance measurements at high angles of incidence without the instrument being influenced by polarized light. The polarizer adapter set is required for the polarizer type I, II, III.
- For UV-2600series/2700series/3600/3600Plus series, SolidSpec Series
* This polarizer is used in the multi-purpose large-sample compartment and absolute reflectance specular attachment.
Name | Effective Diameter | Operable Wavelength Range |
---|---|---|
Large Polarizer Set | 20 mm | 250 to 2300 nm |
Polarizer Type I | 18 mm | 400 to 800 nm |
Polarizer Type II | 17 mm | 260 to 700 nm |
Polarizer Type III | 10 mm | 260 to 2300 nm |
Variable Angle Measurement Unit
This allows measuring transmittance or absolute reflectance of solid samples at any angle of incidence or any angle of receiving light.
- Sample size: 20 to 100nm, thickness 15 mm max.
- Incident angle: 5 to 70 deg. (movable range: 0 to 90 deg.)
- Angle of receiving light: 10 to 140 deg. (movable range: 0 to 180 deg.)
For MPC-2600A
- Photometric accuracy: ±3%
- Wavelength range: 250 to 1400 nm
For MPC-603A
- Photometric accuracy:±1.5%
- Wavelength range: 250 to 1650 nm
For Solidspec series
- Photometric accuracy:±1.5%
- Wavelength range: 250 to 2500 nm