SSG25-50H

Types and main specifications

Part No

346-56752-13

Gauge length (mm)

25

Applicable
sample dNote2
Maximum (mm) : Rod

ø10

Applicable
sample dNote2
Maximum (mm) : Flat plate

W15 x T10

Precision

Guaranteed precision range
JIS B7741 Class 0.5
Measurement range up to 0.3 mm: within ±1.5 μm
Measurement range above 0.3 mm: within ±0.5 % of indicated value

Guaranteed precision range

Usage temperature: 18 to 28 °C, fluctuation: Within ±2 °C

Weight (g)

Approx. 64

Operational temp.
range

5 to 40 °C

Power Requirements

When using the ESA type amplifier: Single-phase 100 V AC 150 VA

Note 1: The case where an amplifier with a range switching function is used is shown.
Note 2: Not applicable to thin films, thin plates or fine wires.

Leer más
Ver menos

SSG25-100H

Types and main specifications

Part No

346-56752-14

Gauge length (mm)

25

Applicable
sample dNote2
Maximum (mm) : Rod

ø10

Applicable
sample dNote2
Maximum (mm) : Flat plate

W15 x T10

Precision

Guaranteed precision range
JIS B7741 Class 0.5
Measurement range up to 0.3 mm: within ±1.5 μm
Measurement range above 0.3 mm: within ±0.5 % of indicated value

Guaranteed precision range

Usage temperature: 18 to 28 °C, fluctuation: Within ±2 °C

Weight (g)

Approx. 72

Operational temp.
range

5 to 40 °C

Power Requirements

When using the ESA type amplifier: Single-phase 100 V AC 150 VA

Leer más
Ver menos

SSG50-10H

Types and main specifications

Part No

346-56752-21

Gauge length (mm)

50

Applicable
sample dNote2
Maximum (mm) : Rod

ø15

Applicable
sample dNote2
Maximum (mm) : Flat plate

W25 x T14

Precision

Guaranteed precision range
JIS B7741 Class 0.5
Measurement range up to 0.3 mm: within ±1.5 μm
Measurement range above 0.3 mm: within ±0.5 % of indicated value

Guaranteed precision range

Usage temperature: 18 to 28 °C, fluctuation: Within ±2 °C

Weight (g)

Approx. 70

Operational temp.
range

5 to 40 °C

Power Requirements

When using the ESA type amplifier: Single-phase 100 V AC 150 VA

Leer más
Ver menos

SSG50-10SH*

Types and main specifications

Part No

346-56752-26

Gauge length (mm)

50

Applicable
sample dNote2
Maximum (mm) : Rod

ø15

Applicable
sample dNote2
Maximum (mm) : Flat plate

W25 x T14

Precision

JIS K7161 measurement range
Up to 200 μm: Accuracy ±1 μm
Measurement range above 200 μm: within ±0.5 % of
indicated value

Guaranteed precision range

Usage temperature: 18 to 28 °C, fluctuation: Within ±2 °C

Weight (g)

Approx. 70

Operational temp.
range

5 to 40 °C

Power Requirements

When using the ESA type amplifier: Single-phase 100 V AC 150 VA

Leer más
Ver menos

SSG75-6SHAD

Types and main specifications

Part No

346-56752-30

Gauge length (mm)

75, 50 variable type

Applicable
sample dNote2
Maximum (mm) : Rod

ø15

Applicable
sample dNote2
Maximum (mm) : Flat plate

W25 x T14

Precision

JIS K7161 measurement range
Up to 200 μm: Accuracy ±1 μm
Measurement range above 200 μm: within ±0.5 % of
indicated value

Guaranteed precision range

Usage temperature: 18 to 28 °C, fluctuation: Within ±2 °C

Weight (g)

Approx. 105

Operational temp.
range

5 to 40 °C

Power Requirements

When using the ESA type amplifier: Single-phase 100 V AC 150 VA

Leer más
Ver menos
{"title":"Descargas de la hoja de especificaciones","description":"Descargue las \u00faltimas hojas de especificaciones.","source":"product","key":3457,"max":"30","filter_types":["spec_sheet"],"link_title":"Ver otras descargas","link_url":""} {"title":"Descargas","description":"Descargue el folleto m\u00e1s reciente.","source":"product","key":3457,"max":"30","filter_types":["brochures"],"link_title":"Ver otras descargas","link_url":"","pdf_links":[]}