    DT Series - Especificaciones

    Differential Transformer Type Extensometers

    Agregar marcador

    DT Series

     

    DT50-50-45

    Measurement range: Max. 25 mm (4 types)Gauge length: 50 mmAccuracy: Extensometer Class 1 (Within ±3 μm or ±1 % of the specified value, whichever is larger)

    Size and Measurement Range for Applicable Samples

    Structure

    A

    Applicable SampleNote) :Rod Diameter (mm)

    ø23 to 45

    Applicable SampleNote) : Flat Plate W × T (mm)

    W 40 (max.) × T 23 to 45

    Measurement Range (mm)

    25

    *1)This Precision is the value when calibrated simultaneously with the amp. Existing amps will require on-site calibration.
    *2)The latest version of amp built into the UH-X/FX and AG-X, or the latest ESA amp, is required for compliance with these DT extensometers. Existing amps may not be compliant.
    *3)These DT extensometers do not accommodate fractures.
    Note: Samples should have enough rigidity so they are not deformed when installing the extensometer.

    Leer más
    Ver menos

    DT50-10-45

    Measurement range: Max. 25 mm (4 types)Gauge length: 50 mmAccuracy: Extensometer Class 1 (Within ±3 μm or ±1 % of the specified value, whichever is larger)

    Size and Measurement Range for Applicable Samples

    Structure

    C

    Applicable SampleNote) :Rod Diameter (mm)

    ø23 to 45

    Applicable SampleNote) : Flat Plate W × T (mm)

    W 40 (max.) × T 23 to 45

    Measurement Range (mm)

    5

    *1)This Precision is the value when calibrated simultaneously with the amp. Existing amps will require on-site calibration.
    *2)The latest version of amp built into the UH-X/FX and AG-X, or the latest ESA amp, is required for compliance with these DT extensometers. Existing amps may not be compliant.
    *3)These DT extensometers do not accommodate fractures.
    Note: Samples should have enough rigidity so they are not deformed when installing the extensometer.

    Leer más
    Ver menos

    DT50-5-45

    Measurement range: Max. 25 mm (4 types)Gauge length: 50 mmAccuracy: Extensometer Class 1 (Within ±3 μm or ±1 % of the specified value, whichever is larger)

    Size and Measurement Range for Applicable Samples

    Structure

    C

    Applicable SampleNote) :Rod Diameter (mm)

    ø23 to 45

    Applicable SampleNote) : Flat Plate W × T (mm)

    W 40 (max.) × T 23 to 45

    Measurement Range (mm)

    2.5

    *1)This Precision is the value when calibrated simultaneously with the amp. Existing amps will require on-site calibration.
    *2)The latest version of amp built into the UH-X/FX and AG-X, or the latest ESA amp, is required for compliance with these DT extensometers. Existing amps may not be compliant.
    *3)These DT extensometers do not accommodate fractures.
    Note: Samples should have enough rigidity so they are not deformed when installing the extensometer.

    Leer más
    Ver menos

    DT50-2-45

    Measurement range: Max. 25 mm (4 types)Gauge length: 50 mmAccuracy: Extensometer Class 1 (Within ±3 μm or ±1 % of the specified value, whichever is larger)

    Size and Measurement Range for Applicable Samples

    Structure

    C

    Applicable SampleNote) :Rod Diameter (mm)

    ø23 to 45

    Applicable SampleNote) : Flat Plate W × T (mm)

    W 40 (max.) × T 23 to 45

    Measurement Range (mm)

    1

    *1)This Precision is the value when calibrated simultaneously with the amp. Existing amps will require on-site calibration.
    *2)The latest version of amp built into the UH-X/FX and AG-X, or the latest ESA amp, is required for compliance with these DT extensometers. Existing amps may not be compliant.
    *3)These DT extensometers do not accommodate fractures.
    Note: Samples should have enough rigidity so they are not deformed when installing the extensometer.

    Leer más
    Ver menos

    DT50-50-25

    Measurement range: Max. 25 mm (4 types)Gauge length: 50 mmAccuracy: Extensometer Class 1 (Within ±3 μm or ±1 % of the specified value, whichever is larger)

    Size and Measurement Range for Applicable Samples

    Structure

    A

    Applicable SampleNote) :Rod Diameter (mm)

    ø6 to 25

    Applicable SampleNote) : Flat Plate W × T (mm)

    W 40 (max.) × T 6 to 25

    Measurement Range (mm)

    25

    *1)This Precision is the value when calibrated simultaneously with the amp. Existing amps will require on-site calibration.
    *2)The latest version of amp built into the UH-X/FX and AG-X, or the latest ESA amp, is required for compliance with these DT extensometers. Existing amps may not be compliant.
    *3)These DT extensometers do not accommodate fractures.
    Note: Samples should have enough rigidity so they are not deformed when installing the extensometer.

    Leer más
    Ver menos

    DT50-10-25

    Measurement range: Max. 25 mm (4 types)Gauge length: 50 mmAccuracy: Extensometer Class 1 (Within ±3 μm or ±1 % of the specified value, whichever is larger)

    Size and Measurement Range for Applicable Samples

    Structure

    C

    Applicable SampleNote) :Rod Diameter (mm)

    ø6 to 25

    Applicable SampleNote) : Flat Plate W × T (mm)

    W 40 (max.) × T 6 to 25

    Measurement Range (mm)

    5

    *1)This Precision is the value when calibrated simultaneously with the amp. Existing amps will require on-site calibration.
    *2)The latest version of amp built into the UH-X/FX and AG-X, or the latest ESA amp, is required for compliance with these DT extensometers. Existing amps may not be compliant.
    *3)These DT extensometers do not accommodate fractures.
    Note: Samples should have enough rigidity so they are not deformed when installing the extensometer.

    Leer más
    Ver menos

    DT50-5-25

    Measurement range: Max. 25 mm (4 types)Gauge length: 50 mmAccuracy: Extensometer Class 1 (Within ±3 μm or ±1 % of the specified value, whichever is larger)

    Size and Measurement Range for Applicable Samples

    Structure

    C

    Applicable SampleNote) :Rod Diameter (mm)

    ø6 to 25

    Applicable SampleNote) : Flat Plate W × T (mm)

    W 40 (max.) × T 6 to 25

    Measurement Range (mm)

    2.5

    *1)This Precision is the value when calibrated simultaneously with the amp. Existing amps will require on-site calibration.
    *2)The latest version of amp built into the UH-X/FX and AG-X, or the latest ESA amp, is required for compliance with these DT extensometers. Existing amps may not be compliant.
    *3)These DT extensometers do not accommodate fractures.
    Note: Samples should have enough rigidity so they are not deformed when installing the extensometer.

    Leer más
    Ver menos

    DT50-2-25

    Measurement range: Max. 25 mm (4 types)Gauge length: 50 mmAccuracy: Extensometer Class 1 (Within ±3 μm or ±1 % of the specified value, whichever is larger)

    Size and Measurement Range for Applicable Samples

    Structure

    C

    Applicable SampleNote) :Rod Diameter (mm)

    ø6 to 25

    Applicable SampleNote) : Flat Plate W × T (mm)

    W 40 (max.) × T 6 to 25

    Measurement Range (mm)

    1

    *1)This Precision is the value when calibrated simultaneously with the amp. Existing amps will require on-site calibration.
    *2)The latest version of amp built into the UH-X/FX and AG-X, or the latest ESA amp, is required for compliance with these DT extensometers. Existing amps may not be compliant.
    *3)These DT extensometers do not accommodate fractures.
    Note: Samples should have enough rigidity so they are not deformed when installing the extensometer.

    Leer más
    Ver menos

    DT50-10-10

    Measurement range: Max. 25 mm (4 types)Gauge length: 50 mmAccuracy: Extensometer Class 1 (Within ±3 μm or ±1 % of the specified value, whichever is larger)

    Size and Measurement Range for Applicable Samples

    Structure

    B

    Applicable SampleNote) :Rod Diameter (mm)

    ø3 to 10

    Applicable SampleNote) : Flat Plate W × T (mm)

    W 40 (max.) × T 0.2 to 10

    Measurement Range (mm)

    5

    *1)This Precision is the value when calibrated simultaneously with the amp. Existing amps will require on-site calibration.
    *2)The latest version of amp built into the UH-X/FX and AG-X, or the latest ESA amp, is required for compliance with these DT extensometers. Existing amps may not be compliant.
    *3)These DT extensometers do not accommodate fractures.
    Note: Samples should have enough rigidity so they are not deformed when installing the extensometer.

    Leer más
    Ver menos

    DT50-5-10

    Measurement range: Max. 25 mm (4 types)Gauge length: 50 mmAccuracy: Extensometer Class 1 (Within ±3 μm or ±1 % of the specified value, whichever is larger)

    Size and Measurement Range for Applicable Samples

    Structure

    B

    Applicable SampleNote) :Rod Diameter (mm)

    ø3 to 10

    Applicable SampleNote) : Flat Plate W × T (mm)

    W 40 (max.) × T 0.2 to 10

    Measurement Range (mm)

    2.5

    *1)This Precision is the value when calibrated simultaneously with the amp. Existing amps will require on-site calibration.
    *2)The latest version of amp built into the UH-X/FX and AG-X, or the latest ESA amp, is required for compliance with these DT extensometers. Existing amps may not be compliant.
    *3)These DT extensometers do not accommodate fractures.
    Note: Samples should have enough rigidity so they are not deformed when installing the extensometer.

    Leer más
    Ver menos

    DT50-2-10

    Measurement range: Max. 25 mm (4 types)Gauge length: 50 mmAccuracy: Extensometer Class 1 (Within ±3 μm or ±1 % of the specified value, whichever is larger)

    Size and Measurement Range for Applicable Samples

    Structure

    B

    Applicable SampleNote) :Rod Diameter (mm)

    ø3 to 10

    Applicable SampleNote) : Flat Plate W × T (mm)

    W 40 (max.) × T 0.2 to 10

    Measurement Range (mm)

    1

    *1)This Precision is the value when calibrated simultaneously with the amp. Existing amps will require on-site calibration.
    *2)The latest version of amp built into the UH-X/FX and AG-X, or the latest ESA amp, is required for compliance with these DT extensometers. Existing amps may not be compliant.
    *3)These DT extensometers do not accommodate fractures.
    Note: Samples should have enough rigidity so they are not deformed when installing the extensometer.

    Leer más
    Ver menos