Shim-pack Scepter LC Columns - Características
HPLC Column
-
Eight stationary phases and 3 column hardware types for extensive sample coverage
-
Utilize excellent stability & performance under a wide range of LC conditions
-
Superior Sensitivity and Separation Performance in metal-coordinating compounds
-
Wide-pore reversed-phase column optimized for analysis of middle-molecular-weight compounds and proteins
Eight stationary phases and 3 column hardware types for extensive sample coverage
Shim-pack Scepter Chemistries
Shim-pack Scepter | Reveresd Phase | HILIC | ||||||
---|---|---|---|---|---|---|---|---|
C18-120 | C18-300 | HD-C18-80 | C8-120 | C4-300 | Phenyl | PFPP | Diol-HILIC | |
Ligand Type | Trifunctional C18 | Trifunctional C18 | Trifunctional C18 | Trifunctional C8 | Trifunctional C4 | Trifunctional Phenylbutyl |
Trifunctional Pentafluorophenylpropyl |
Trifunctional Dihydroxypropyl |
General Purpose | General Purpose for Large Molecules | High Density Type for Increased Retention | ||||||
Particle | Organic Silica Hybrid | |||||||
Particle Size | 1.9 μm, 3 μm, 5 μm | |||||||
Pore Size | 12 nm (120Å) | 30 nm (300Å) | 8 nm (80Å) | 12 nm (120Å) | 30 nm (200Å) | 12 nm (120Å) | ||
End Capping | Proprietary | None | ||||||
Carbon% | 20 | N.D. | 25 | 17 | N.D. | 17 | 15 | 12 |
pH Range | 1 - 12 | 1 - 10 | 1 - 8 | 2 - 10 | ||||
100 % Aqueous Condition | YES | YES | × | × | YES | YES | YES | — |
USP Classification | L1 | L1 | L1 | L7 | L26 | L11 | L43 | L20 |
Shim-pack Scepter Column Hardware
Scepter | Scepter Claris | Scepter [metal-free] | |
---|---|---|---|
|
|
|
|
Wetted materials for body | Stainless steel | Bioinert coating | PEEK |
Wetted materials for frit | Stainless steel | Bioinert coating | PEEK |
Utilize excellent stability & performance under a wide range of LC conditions
With excellent stability under a wide range of LC conditions, Shim-pack Scepter LC columns are effective for method scouting combining mobile phase pH and organic modifier.
【 Comparison of Chromatograms using Gradient condition with Acetonitrile 】
C18 | HD-C18 | C8 | Phenyl | PFPP | |
---|---|---|---|---|---|
pH
2.9
|
|||||
pH
6.1
|
|||||
pH
9.9
|
Outside of
recommended pH |
Analytes
1. Saccharin (pKa = 2.2)
2. Dextromethorphan (pKa = 8.3)
3. Amitriptyline (pKa = 9.4)
4. N-Butyl paraben (pKa = 8.3)
5. Ibupurofen (pKa = 4.4)
Superior Sensitivity and Separation Performance in metal-coordinating compounds
Shim-pack Scepter Claris
Shim-pack Scepter Claris features a column body with a newly-developed bioinert coating packed with Scepter series stationary phases.
- Bioinert coating is applied to the column body and stainless steel frit.
- Ideal for analysis of metal-coordinating and hydrophobically adsorbing compounds such as nucleic acids, proteins, and lipids
- Outstanding pH and lifetime stability due to Scepter organic silica hybrid packing
Superior Sensitivity and Separation Performance in Nucleic Acid Analysis
Shim-pack Scepter Claris C18-120 with the bioinert coating and Scepter C18-120 with traditional stainless steel hardware were compared in this example of analysis of synthetic oligonucleotide. Results from Claris were highly sensitive and reproducible from the first injection, with no loss of sample signal. Scepter C18-120 in a stainless steel column body produced low sensitivity results and showed adsorption from the first sample injection.
Wide-pore reversed-phase column optimized for analysis of middle-molecular-weight compounds and proteins
Shim-pack Scepter C18-300, C4-300
- Shim-pack Scepter C18-300 and C4-300 are wide-pore organic silica hybrid reversed phase columns recommended for the separation of proteins such as monoclonal antibodies and mid-sized molecules such as oligonucleic acids and peptides that may not be retained on 100-120Å pore size columns due to size-exclusion effects. The organic silica hybrid base material is highly stable even at high temperatures under acidic and basic mobile phase conditions. Pore sizes are optimized for large molecular weight compounds and dispersed uniformly in the column, resulting in symmetrical peak shapes and increased resolution of antibodies and nucleic acids compared to a smaller pore size column. Shim-pack Scepter C18-300 and C4-300 are also effective for high-sensitivity LC/MS analysis, producing good peak shapes even under weak ionpairing conditions using a formic acid mobile phase.
-
C18-300 C4-300 Ligand Type Trifunctional C18 Trifunctional C4 Generic Purpose Type Generic Purpose Type Particle Size 1.9, 3, 5 μm Pore Size 300Å End Capping Proprietary pH Range 1-12 100% aqueous condition YES USP Classification L1 L26
Peptide Analysis Example
Shim-pack Scepter C18-300 and C4-300 made with 300 Å (30 nm) pore size packing material. The larger pore size is recommended for the analysis of mid-sized and large-sized molecules with molecular weights above 5000 to enable retention and avoid size-exclusion effects. This analysis of a mixed sample of four different peptides and proteins demonstrated good peak shapes and favorable separation of insulin and ribonuclease A due to the pore size that was large enough to allow proper diffusion of these large molecular weight compounds.