GCMS-TQ8040 NX - Características

Triple Quadrupole Gas Chromatograph Mass Spectrometer

Add Bookmark

Simplified user maintenance allows operators to change parts quickly

 

Active-Time Management™ That Accurately Determines Operation Time

Time Management during Instrument Startup/Shutdown

The mass spectrometer has to be operated in a vacuum condition, the startup and stopping of the system takes time depending on the condition. Determining this can be a challenge. Since the amount of time that the system takes when starting up or stopping is displayed in real time, it is easy to accurately determine when maintenance of the ion source or analysis is possible. Moreover, tasks that until now needed to be performed by the user, such as leak checks upon system startup and auto tuning, are now performed automatically.

Time Management during Injection Port Maintenance

The Easy sTop function, used to safely maintain the sample injection port without releasing the vacuum, displays the remaining time (coolingdown time) when the septum or the insert can be replaced in real time. Maintenance time can be minimized by understanding the accurate remaining time.
Furthermore, by using a ClickTek nut on the top of the sample injection port, the port can be opened or closed without tools, by simply using fingers to twist a lever. That enables faster and easier insert replacement than ever before.



 


Easy sTop Function


ClickTek Nut

Time Management for Continuous Analysis

By displaying the time required for continuous analysis in real time, the time when the current continuous analysis will finish can be accurately confirmed. This increases the instrument operating time (active time) by reducing standby time required during continuous analysis or while switching between different users. In addition, because this function makes it easier to schedule the timing for analysis preparations, such as sample preparation and pretreatment, based on the finish time of the previous analysis, it enables analytical processes to be performed more efficiently, which can help improve work-life balance.



 


Time display for continuous analysis can be used only in liquid injection using AOC-20i.

Smart Database Series provides automated method development

 

Smart Database

The Shimadzu "Smart Database" is a database file for creating the method files using "Smart MRM" function. In addition to compound information and transitions, retention index can be registered in the database file. Method creation can be proceeded without calculating the retention time by analyzing the standard samples when using the Automatic Adjustment Retention Time (AART) function. In addition to MRM information, Scan and SIM ion information, mass spectra and calibration curve information from the internal standard method can also be registered in the database file. This allows users to create their own database easily.



 

Smart MRM sets method to maximize sensitivity

 

Smart MRM

Smart MRM makes method development quick and easy. Whether starting from scratch to optimize transitions and collision energies for new compounds, or starting from an MRM database of known target analytes to build a custom MRM method, Smart MRM takes the stress and difficulty out of method development.

{"title":"Descargas","description":"Descargue el folleto m\u00e1s reciente.","source":"product","key":3273,"max":"30","filter_types":["brochures"],"link_title":"Ver otras descargas","link_url":"","pdf_links":[]}